The smoke detector from infrared barrier for light reflection in a mirror, certified accordingto EN 54-12.
The barrier is designed to be installed between 0.3 m to 0.6 m from the ceiling and parallel to it. The lateral coverage of the barrier is maximum 7.5 m for each side, meaning that with a single point of connection, we can cover 750m2/1500m2 according to the model.
All the barriers include test filters, mounting support brackets and reflector.
Automatic compensation of dirt and three levels of sensitivity adjustment.
Consumption 4 mA, on idle and 14 mA in alarm.
The smoke detector from infrared barrier for light reflection in a mirror, certified accordingto EN 54-12.
The barrier is designed to be installed between 0.3 m to 0.6 m from the ceiling and parallel to it. The lateral coverage of the barrier is maximum 7.5 m for each side, meaning that with a single point of connection, we can cover 750m2/1500m2 according to the model.
All the barriers include test filters, mounting support brackets and reflector.
Automatic compensation of dirt and three levels of sensitivity adjustment.
Consumption 4 mA, on idle and 14 mA in alarm.
Optical Smoke Detector, LPCB certified, according to EN54-7 norm.
Low profile detectors with an attractive design, manufactured with SMD technology,they have dual LED, remote alarm output with an interchangeable, easily connected same base.
Socket and dust protector, included.
- Connection to 2 wires.
- Power supply between 15 and 35 VCC.
- Power consumption: 35 μA (at rest), 80 mA (alarm).
- Dimension: Ø 99 mm, height including the base: 46 mm.
Optical Smoke and Heat detector (Class A), LPCB certified, according to EN54- 5 and EN54-7 norms.
Low profile detectors with an attractive design, manufactured with SMD technology, they have dual LED, remote alarm output with an interchangeable, easily connectedsame base.
Socket and dust protector included.
- Connection to 2 wires.
- Power supply between 15 and 35 Vdc.
- Power consumption: 35 μA (at rest), 80 mA (alarm).
- Dimensions: Ø 99 mm, height including the base: 61 mm.
Thermal detector for heat (class A2R). LPCB certificates, according to EN54-5 norm.
Manufactured with SMD technology, they have dual LED, remote alarm output with an interchangeable, easily connected same base.
Socket and dust cover included.
- Connection to 2 wires.
- Power supply between 15 and 35 V CC.
- Power consumption: 35 μA (at rest), 80 mA (alarm).
- Dimensions: Ø 99 mm, height including the base: 46 mm.
Manufactured by Aguilera Electronica in ABS equipped with bayonet type coupling,nuts and washers for the connection of cables, all in stainless steel.
Enables the exchange of conventional detectors.
It is supplied according to needs: This version has a 22 mm height, which allows theentry of a side tube, for openly viewed cable ducts and 10 mm lower version, with onlyupper entry for built-in or in dropped ceiling cable ducts.
Manufactured by Aguilera Electronica in ABS equipped with bayonet type coupling,nuts and washers for the connection of cables, all in stainless steel.
Enables the exchange of conventional detectors.
It is supplied according to needs: This version has a 22 mm height, which allows theentry of a side tube, for openly viewed cable ducts and 10 mm lower version, with onlyupper entry for built-in or in dropped ceiling cable ducts.
Developed and manufactured by A. Electronica under Norm UNE EN54-7.
Certified by AENOR.
Consisting of a dark chamber, designed with a labyrinth that allows the smoke to enter, but not the light, provided with both, a transmitter and a receiver, they are operatingon the principle of scattered light, having a circuit with the appropriate electronics forproper monitoring.
Output for remote alarm indicator, voltage stabilizer and automatic operation monitoring, the visible LED light is locked, when an alarm is entering, mounted on a white ABShousing of Ø 105 x 68 mm high.
Maximum power consumption:180 μA at rest and 22 mA in alarm.”
Manufactured by AGUILERA ELECTRONICA. This equipment is made of an AE002/OP optical detector and a metal box, fitted with an alarm indication lamp, fittings for theentrance of cables and probe ducts, which take samples from inside the ducts..
Developed and manufactured by A. Electronica under Norm UNE EN54-7.
Certified by AENOR.
Consisting of a dark chamber, designed with a labyrinth that allows the smoke to enter, but not the light, provided with both, a transmitter and a receiver, they are operatingon the principle of scattered light, having a circuit with the appropriate electronics for proper monitoring.
Output for remote alarm indicator, voltage stabilizer and automatic operation monitoring, the visible LED light is locked, when an alarm is entering, mounted on a white ABShousing of Ø 105 x 68 mm high.
Maximum power consumption:180 μA at rest and 22 mA in alarm. Version with automatic reset
Designed and manufactured by Aguilera Electronica under UNE EN54-7 norm,certified by AENOR.
When it detects a sudden rise in temperature or when the rise is very slow and the 58°C degrees are reached, it gives an alarm signal. Equipped with LED indicator alarmwith interlocking, automatic check of functions, voltage stabilizer and automatic alarm output for connecting remote action indicators.
Mounted on a white ABS housing of Ø 105 x 45 mm high.
Power consumption: 50 μA on idle and 22 mA in alarm.
Designed and manufactured by Aguilera Electronica under UNE EN54-7 norm,certified by AENOR.
When it detects a sudden rise in temperature or when the rise is very slow and the 58°C degrees are reached, it gives an alarm signal. Equipped with LED indicator alarmwith interlocking, automatic check of functions, voltage stabilizer and automatic alarm output for connecting remote action indicators.
Mounted on a white ABS housing of Ø 105 x 45 mm high.
Power consumption: 50 μA on idle and 22 mA in alarm.
Low power consumption flash: 88 mA. Luminous intensity: 10 Cd.Dimensions: Ø 106 mm, height: 91 mm.Protection: IP54 (with low base) IP65 (with high base)
Flash EN 54-23 certified for ceiling mounting. Type C-3-7.5. Maximum height for installation 3m, length of coverage 7.5 m. Led technology which guarantees light intensity 0.4lux/m2 in the whole area. Flash frequency selectable between 1Hz and 0.5Hz. Maximum consumption 25mA. IP33 protection with low base, IP65 with high base.
Flash EN 54-23 certified for wall mounting. Type W-2.4-7.5. Maximum height for installation 2.4m, length of coverage 7.5 m. Led technology which guarantees light intensity 0.4lux/m2 in the whole area. Flash frequency selectable between 1Hz and 0.5Hz. Maximum consumption 25mA. IP33 protection with low base, IP65 with high base.