Optical smoke barrier, transmitter – receiver 100m

Certified according to EN54-12. They have three configurable darkening alarm levels at 25%, 35% and 50%.

  • Range from 10 to 100 meters.
  • Operation from 11.5 to 28 V DC, low power consumption.
  • Automatic compensation for dirt.
  • Different levels of adjustment for more sensitivity.
  • Unit of control of easy access.
  • Complies with BS5839, Part 5 norm, approved by C.P.D.
  • Maximum consumption on idle, < 8.5 mA, while in alarm,< 16.5 mA.

ATEX optical smoke curtain

Optical smoke curtain transmitter-receiver, with the same characteristics as the barrierAE/BO100 with an ATEX Ex II2 G certification and EExd IIBT6

Referencia: AE/BO5000-50A

Motorized optical curtain

The infrared barrier for smoke detection by reflection with automatic alignment AE/BO5000 consists of a transmitter, a control unit for its installation at ground leveland a mirror reflector. Approved and certified according to the EN 54-12 norm.

  • Alignment assisted by a built-in laser pointer.
  • Auto-alignment of the curtain and “”Auto-Optimise”” system for automatic fine tuning.
  • Fastening system “Easifit”.
  • Maximum consumption on idle: 12 mA and 52 mA, in alarm.
  • The control unit supports up to 4 transmitters.
  • For distances smaller than 50 m, a mirror is necessary.
  • For distances up to 100 m, four mirrors are necessary.
Referencia: AE/BO5000-E

1 emisor + 1 espejo

Se compone de un emisor, una unidad de control para su instalación a nivel del suelo y un espejo reflector. Certificada y homologada según norma EN 54-12.

  • Alineación asistida por puntero láser incorporado.
  • Compensación automática de la suciedad.
  • Auto-alineación de la barrera y sistema “AutoOptimise” para ajuste fino automático.
  • Sistema de fijación “Easifit”.
  • Consumo máximo en reposo 12mA y en alarma 52mA.
  • La unidad de control admite hasta 4 emisores.
  • Para distancias < 50 m es necesario un espejo.
  • Para distancias hasta 100 m son necesarios 4 espejos.

Infrared optical barrier by reflection

Infrared optical barrier by reflection for smoke detection. Certified in accordance with EN54-12. Range depending on the model up to 50m or 100m. A laser pointer is supplied for easier adjustment. Provided with three sensitivity levels. Output for remote indicator. Consumption in standby: 19mA, Consumption in Alarm: 54Ma

Infrared optical barrier by reflection

Infrared optical barrier by reflection for smoke detection. Certified in accordance with EN54-12. Range depending on the model up to 50m or 100m. A laser pointer is supplied for easier adjustment. Provided with three sensitivity levels. Output for remote indicator. Consumption in standby: 19mA, Consumption in Alarm: 54Ma

Infrared smoke barrier by reflection (de 10 a 100m)

The smoke detector from infrared barrier for light reflection in a mirror, certified accordingto EN 54-12.

The barrier is designed to be installed between 0.3 m to 0.6 m from the ceiling and parallel to it. The lateral coverage of the barrier is maximum 7.5 m for each side, meaning that with a single point of connection, we can cover 750m2/1500m2 according to the model.

All the barriers include test filters, mounting support brackets and reflector.

Automatic compensation of dirt and three levels of sensitivity adjustment.

Consumption 4 mA, on idle and 14 mA in alarm.

Infrared smoke barrier by reflection (10 to 50m)

The smoke detector from infrared barrier for light reflection in a mirror, certified accordingto EN 54-12.

The barrier is designed to be installed between 0.3 m to 0.6 m from the ceiling and parallel to it. The lateral coverage of the barrier is maximum 7.5 m for each side, meaning that with a single point of connection, we can cover 750m2/1500m2 according to the model.

All the barriers include test filters, mounting support brackets and reflector.

Automatic compensation of dirt and three levels of sensitivity adjustment.

Consumption 4 mA, on idle and 14 mA in alarm.

Referencia: AE/C5-OP

Optical smoke detectors

Optical Smoke Detector, LPCB certified, according to EN54-7 norm.
Low profile detectors with an attractive design, manufactured with SMD technology,they have dual LED, remote alarm output with an interchangeable, easily connected same base.

Socket and dust protector, included.

  • Connection to 2 wires.
  • Power supply between 15 and 35 VCC.
  • Power consumption: 35 μA (at rest), 80 mA (alarm).
  • Dimension: Ø 99 mm, height including the base: 46 mm.
Referencia: AE/C5-OPT

Optical heat detector

Optical Smoke and Heat detector (Class A), LPCB certified, according to EN54- 5 and EN54-7 norms.
Low profile detectors with an attractive design, manufactured with SMD technology, they have dual LED, remote alarm output with an interchangeable, easily connectedsame base.

Socket and dust protector included.

  • Connection to 2 wires.
  • Power supply between 15 and 35 Vdc.
  • Power consumption: 35 μA (at rest), 80 mA (alarm).
  • Dimensions: Ø 99 mm, height including the base: 61 mm.
Referencia: AE/C5-TV

Rate and rise detector

Thermal detector for heat (class A2R). LPCB certificates, according to EN54-5 norm.

Manufactured with SMD technology, they have dual LED, remote alarm output with an interchangeable, easily connected same base.

Socket and dust cover included.

  • Connection to 2 wires.
  • Power supply between 15 and 35 V CC.
  • Power consumption: 35 μA (at rest), 80 mA (alarm).
  • Dimensions: Ø 99 mm, height including the base: 46 mm.
Referencia: AE/ZCA

Sockets conventionals ( 22 mm.)

Manufactured by Aguilera Electronica in ABS equipped with bayonet type coupling,nuts and washers for the connection of cables, all in stainless steel.

Enables the exchange of conventional detectors.

It is supplied according to needs: This version has a 22 mm height, which allows theentry of a side tube, for openly viewed cable ducts and 10 mm lower version, with onlyupper entry for built-in or in dropped ceiling cable ducts.

Referencia: AE/ZCB

Sockets conventionals (10 mm.)

Manufactured by Aguilera Electronica in ABS equipped with bayonet type coupling,nuts and washers for the connection of cables, all in stainless steel.

Enables the exchange of conventional detectors.

It is supplied according to needs: This version has a 22 mm height, which allows theentry of a side tube, for openly viewed cable ducts and 10 mm lower version, with onlyupper entry for built-in or in dropped ceiling cable ducts.

Optical smoke detector at 24V

Developed and manufactured by A. Electronica under Norm UNE EN54-7.

Certified by AENOR.

Consisting of a dark chamber, designed with a labyrinth that allows the smoke to enter, but not the light, provided with both, a transmitter and a receiver, they are operatingon the principle of scattered light, having a circuit with the appropriate electronics forproper monitoring.

Output for remote alarm indicator, voltage stabilizer and automatic operation monitoring, the visible LED light is locked, when an alarm is entering, mounted on a white ABShousing of Ø 105 x 68 mm high.
Maximum power consumption:180 μA at rest and 22 mA in alarm.”