Referencia: AEC-H240

H9650-type detector cable

Fluoropolymer-based coverage, very resistant to abrasion and to chemical products, for use in extremely aggressive environments and to high temperatures.

  • It resists anyweather and direct sunlight.
  • Maximum environmental temperature: 200 ºC

AEC-H240. H9650-type detector cable L AEC-H240.

H9650-type detector cable L 1.520 – 3.039 m tº pr/al. 240 ºC

AEC-H240. H9650-type detector cable L >3.040 m tº pr/al. 240 ºC

Referencia: AEC-SA

Adhesive support

AEC-SA. Adhesive support (a plastic clamp and glue required)
AEC-P. (glue for the AEC-SA)

Referencia: AEC-SB

Support for cable trays – Mounting support

  • AEC-SBN (narrow mounting bracket. Metal + Clip)
  • AEC-SBW (wide mounting bracket. Metal + Clip)
  • AEC-SBET (narrow with screw and lock nut)
  • AEC-SBAT (wide with screw and lock nut)
Referencia: AEC-SL

Support in “L”

AEC-SLHN. Support in “L”in zincked iron and with an AE-CCN clip
AEC-SLHN. Support in “L” in stainless steel and with a clip AE-CCN

Referencia: AEC-SR

Supports

AEC-SRG. Support galvanized with American-type thread
AEC-SRAI. Support in stainless steel with American-type thread

Referencia: AEC-SV

Support for beams or trays

  • AEC-SVA. Support for beams or trays in steel
  • AEC-SVHP. Support for beams or trays in zincked iron and with an AE-CCN clip
  • AEC-SVHN. Support for beams or trays in zincked iron and with an AE-CCN clip
Referencia: AEC-T

Tensors

AEC-TG. Galvanized Tensor
AEC-TAI. stainless steel with aluminium body tensor

Detector cable TRI- type

Model firing at a low-temperature. External covering out of vinyl polymer. The protective cover is prepared to resist moisture at low temperatures, providing an excellent performance. Suitable for applications in refrigerated chambers.

  • Tested at temperatures of -51ºC.
  • Cable with dual temperature that detects two temperature levels offering a prealarm  and an alarm, cover made of vinyl, resistant to common chemical aggressive agents.

 

ALARM TEMPERATUREREFERENCE
68/93 ºCAEC-TRI6893
68/93ºC cable clampAEC-TRI6893M
Referencia: AEC-XCR

XCR- type detector cable

Fluoropolymer-based coverage, very resistant to abrasion and to high temperatures, for use in extremely aggressive environments. Resists any weather.

 

ALARM TEMPERATUREREFERENCE
68 ºCAEC-XCR68
68 ºC con cable clampAEC-XCR68M
88 ºCAEC-XCR88
88 ºC con cable clampAEC-XCR88M
105 ºCAEC-XCR105
105 ºC con cable clampAEC-XCR105M
138 ºCAEC-XCR138
138 ºC con cable clampAEC-XCR138M
180 ºCAEC-XCR180
180 ºC con cable clampAEC-XCR180M
Referencia: AECL-ADW1

Control unit for linear temperature detector (1sensor tube)

Thermovelocimetric temperature detector, working depending upon changes in gas pressure, as a function of temperature. It permits the detection of differential temperature changes, from a programmed level of temperature.

The system consists of a copper sensor tube, stainless steel or Teflon (depending on the environmental conditions) of up to 130 meters long and its corresponding detector.

The detector includes: a pump that increases the pressure in the sensor tube, an electronic sensor that continuously measures the absolute pressure inside the tube and a microprocessor that performs the evaluation of data and activates the alarm, it filters the disturbing factors, such as climatic temperature variations and it detects anydamage that may arise in the sensor tube.

Characteristics:

  • Supply voltage: 9 at 30 Vdc
  • Range of environmental temperature: – 20 ºC to +70 ºC
  • Range of temperature for sensor tube: -40 ºC to +300 ºC
  • Dimensions: 134 x 250.5 x 160.5 mm.
  • Level of protection of the cabinet: IP65• Weight: 1.6 Kg
Referencia: AECL-ADW2

Control unit for linear temperature detector (2 sensor tube)

Thermovelocimetric temperature detector, working depending upon changes in gas pressure, as a function of temperature. It permits the detection of differential temperature changes, from a programmed level of temperature.

The system consists of a copper sensor tube, stainless steel or Teflon (depending on the environmental conditions) of up to 130 meters long and its corresponding detector.

The detector includes: a pump that increases the pressure in the sensor tube, an electronic sensor that continuously measures the absolute pressure inside the tube and a microprocessor that performs the evaluation of data and activates the alarm, it filters the disturbing factors, such as climatic temperature variations and it detects anydamage that may arise in the sensor tube.

Characteristics:

  • Supply voltage: 9 at 30 Vdc
  • Range of environmental temperature: – 20 ºC to +70 ºC
  • Range of temperature for sensor tube: -40 ºC to +300 ºC
  • Dimensions: 134 x 250.5 x 160.5 mm.
  • Level of protection of the cabinet: IP65• Weight: 1.6 Kg

Linear detector control unit EX I

Version of AECL-ADW detector for Ex-I areas, with identical characteristics
except:

  • Dimensions: 450 x 210 x 205 mm. Weight: 13 Kg.
  • Level of protection of the cabinet: II G2 EEx of IIC T6 or T5.