Kit IP52 for TITANUS PRO·SENS® and TOP·SENS® detectors.
Archivos
Protection kit against dust
Protection kit against dust for TITANUS PRO·SENS® and TOP·SENS® detectors.
Silencer for ducts
Silencer for ducts. It reduces by 10 dB(A) the sound level.
Dimensions: 120x120x95mm
Filter for flame arresters group II-A
Filter for flame arresters for Titanus ProSens and topsens duct network, specific for group areas II-A.
Door contact switch
Door contact switch
Algorithmic loop card
Micro-processed unit designed to integrate the TITANUS detectors into the algorithmic loop of the central units of the SA series of Aguilera Electronica.
Independently from each detector´s module, it reports the status and the level, as wellas it manages the remote reset of the detector. It´s valid for all the TITANUS detectorsof the TOP·SENS® and PRO·SENS® series.
The module is housed inside the TITANUS box of detectors, being connected to the detector through a flat ribbon cable while it incorporates a 2-pin terminal for the connection to the loop algorithm.
Ethernet network card
Ethernet network card for integrating the TITANUS PRO·SENS® TP4 and TP5 detectors,TOP·SENS® and SUPER·SENS® in a VISULAN® or VISULAN® T control network.
It is housed inside the TITANUS detector box.
Ethernet network card
Ethernet network card for integrating the TITANUS MICRO·SENS®, in a VISULAN® or VISULAN® T control network.
It is housed in an additional box.
Microsens room-ident relay card
Card equipped with 5 relays with voltage free contacts for a repeated identification of the room (ROOM-IDENT) on a MICRO · SENS ® detector
Microsens relay card
Card equipped with 5 relays with tension free contacts appropriate repeated signalsof alarm, pre-alarm and fault on a MICRO·SENS ® detector.
Visulan T OPC server
Interface software for the integration of TITANUS networks based on Visulan T, in OPC applications via TCP / IP connection.
Control Software
Graphics software VISULAN T for the visualization and control of the TITANUS aspiration detectors.
It allows for the integration of up to 250 TITANUS detectors in an Ethernet network.
Visualization in a window of the device localization. Specific diagram of each detector showing its state, smoke level, fluid level, faults, signs of alarm…
Valid for Windows XP, Windows Vista & Windows 7.
AETM Titanus Microsens
TITANUS MICRO·SENS® has been developed to monitor small and medium size of installations & premises. However, it provides many different features and operating options, such as:
- A version with ROOM·IDENT allows the localization of fire with the precision of asingle smoke detector point.
- A version for use in freezer chambers allows the use in applications below – 40 ºC.
- The compatibility with Ethernet networks through this device allows for integration with external monitoring systems.
With a TITANUS MICRO·SENS® system can be replaced up to 8 single smoke detectors. For that reason duct lengths of up to 50 m will be provided, whether required A, or B, or C, or not, according to EN 54-20.
Designed for applications which require fire detection individually for a given area, for small to medium enclosures of up to 400 m2, equipments, up to 5 contiguous premises (hotel rooms …), autonomous equipments (wind turbines, transformers …)
Specifications:
- Energy supply: 24V CC (14 – 30 V CC)
- Max. power consumption at rest: 105 mA
- Max. power consumption of alarm: 110-140 mA
- Dimensions: 140x222x70 mm
- Weight: 850 to 895 gr
- Temperature interval: -20ºC to +60ºC
- Humidity: from 10% to 95% without condensation.
- Two levels of alarm (alarm and pre-alarm).
- Relay switch free of output voltage for alarm and general fault alarm.
- Class of protection: up to IP 54.
- EN 54-20 certificates, classes A, B, C, nº 0786-CPD-20322.
- VdS Approval nº G 206004
REFERENCE | SENSITIVITY | LEVEL INDICATOR | ROOM IDENT. |
AETM-50I | 0.5% | NO | SI |
AETM-50B | 0.5% | SI | NO |
AETM-50BI | 0.5% | SI | SI |
AETM-10 | 0.1% | NO | NO |
AAETM-10I | 0.1% | NO | SI |
AETM-10B | 0.1% | SI | NO |
AETM-10BI | 0.1% | SI | SI |
Microsens for a refrigerated environment
REFERENCE | SENSITIVITY | LEVEL INDICATOR |
AETM-F50 | 0.5% | NO |
AETM-F50B | 0.5% | SI |
AETM-F10 | 0.1% | NO |
AETM-F10B | 0.1% | SI |
Titanus Prosens
TITANUS PRO·SENS® has been developed for a broad range of applications.
The high modularity of the system offers an economical solution tailored to individual customer needs.
It offers the following options:
- Connection to one or two detector modules. With just one device we can monitor two areas, or even double detection in the same area (by using the adapter in “Y” AET-P01109255 mode).
- From 1 to 3 levels of alarm (warning, pre-alarm and alarm) with relays switched free of voltage, depending on the model, for each detector module.
- Fault Detector Relay.
- Ethernet network connection, using AET / IT network card (not for TP1 models).
- Connection to Aguilera Electronica´s algorithmic loop through the card AE/SAIT.
- Specific version for refrigerated zones, which can be used in applications up to -40ºC.
- Silent version, with a noise level of 23 dB (A).
Specifications:
- Energy supply: 24V CC (14 – 30)
- Dimensions: 200x292x113 mm
- Temperature interval: -20ºC to +60ºC
- Humidity: from 10% to 95% without condensation.
- Certificates EN 54-20, classes A, B, C, nº 0786-CPD-20685.
- VdS Approval nº G 202064
- Max. number of aspiration openings: 32
- Max. duct length: 300 m
- Consumption at rest: 200 mA
- Maximum power consumption in alarm: 210 mA””
REFERENCE | SENSITIVITY |
AETP1-50 | 0.5% |
AETP1-10 | 0.1% |
AETP1-01 | 0.015% |
REFERENCE | SENSITIVITY |
AETP1-F50 | 0.5% |
AETP1-F10 | 0.1% |
AETP1-F01 | 0.015% |
- Max. number of aspiration openings 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 220 mA
- Maximum power consumption in alarm: 240 mA
REFERENCE | MODULE 1 | MODULE 2 |
AETP1-2-50 | 0.5% | 0.5% |
AETP1-2-1050 | 0.1% | 0.5% |
AETP1-2-10 | 0.1% | 0.1% |
AETP1-2-0150 | 0.15% | 0.5% |
AETP1-2-0110 | 0.15% | 0.1% |
AETP1-2-01 | 0.15% | 0.15% |
REFERENCE | MODULE 1 | MODULE 2 |
AETP1-F2-50 | 0.5% | 0.5% |
AETP1-F2-1050 | 0.1% | 0.5% |
AETP1-F2-101 | 0.1% | 0.1% |
AETP1-F2-0150 | 0.15% | 0.5% |
AETP1-F2-0110 | 0.15% | 0.1% |
AETP1-F2-01 | 0.15% | 0.15% |
Titanus Prosens TP1 type – 2 detection modules for refrigerated environment
REFERENCE | MODULE 1 | MODULE 2 |
AETP1-2-D5050 | 0.5% | 0.5% |
AETP1-2-D1050 | 0.1% | 0.5% |
AETP1-2-D0150 | 0.15% | 0.5% |
AETP1-2-D0110 | 0.015% | 0.1% |
- Max. number of aspiration openings 32
- Max. duct length: 300 m
- Consumption at rest: 210 mA
- Maximum power consumption in alarm: 220 mA
REFERENCE | SENSITIVITY |
AETP4-50 | 0.5% |
AETP4-10 | 0.1% |
AETP4-01 | 0.015% |
- Max. number of aspiration openings: 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 240 mA
- Maximum power consumption in alarm: 250 mA
REFERENCE | SENSITIVITY |
ARTP4-F50 | 0.5% |
ARTP4-F10 | 0.1% |
ARTP4-F01 | 0.015% |
- Max. number of aspiration openings: 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest 240 mA
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP4-2-50. | 0.5% | 0.5% |
AETP4-2-1050 | 0.1% | 0.5% |
AETP4-2-10 | 0.1% | 0.1% |
AETP4-2-0150 | 0.015% | 0.5% |
AETP4-2-0110 | 0.015% | 0.1% |
AETP4-2-01 | 0.015% | 0.015% |
- Max. number of aspiration openings: 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 240 mA
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP4-2-D5050 | 0.5% | 0.5% |
AETP4-2-D1050. | 0.1% | 0.5% |
AETP4-2-D0150 | 0.015% | 0.5% |
AETP4-2-D0110 | 0.015% | 0.1% |
- Max. number of aspiration openings: 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 240 mA
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP4-F2-50 | 0.5% | 0.5% |
AETP4-F2-1050 | 0.1% | 0.5% |
AETP4-F2-10 | 0.1% | 0.1% |
AETP4-F2-0150 | 0.015% | 0.5% |
AETP4-F2-0110 | 0.015% | 0.1% |
AETP4-F2-01 | 0.015% | 0.015% |
- Max. number of aspiration openings: 32
- Max. duct length: 300 m
- Consumption at rest: 210 mA
- Maximum power consumption in alarm: 220 mA
REFERENCE | SENSITIVITY |
AETP5-50 | 0.5% |
AETP5-10 | 0.1% |
AETP5-01 | 0.015% |
- Max. number of aspiration openings: 32
- Max. duct length: 300 m
- Consumption at rest: 210 mA
- Maximum power consumption in alarm: 220 mA
REFERENCE | SENSITIVITY |
AETP5-F50 | 0.5% |
AETP5-F10 | 0.1% |
AETP5-F01 | 0.015% |
- Max. number of aspiration openings: 64 (2 x 32)/li>
- Max. duct length: 560 m (2 x 280)/li>
- Consumption at rest: 240 mA/li>
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP5-2-50 | 0.5% | 0.5% |
AETP5-2-1050 | 0.1% | 0.5% |
AETP5-2-10 | 0.1% | 0.1% |
AETP5-2-0150 | 0.015% | 0.5% |
AETP5-2-0110 | 0.015% | 0.1% |
AETP5-2-01 | 0.015% | 0.015% |
- Max. number of aspiration openings: 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 240 mA
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP5-2-D1050 | 0.1% | 0.5% |
AETP5-2-D0150 | 0.015% | 0.5% |
AETP5-2-D0110 | 0.015% | 0.1% |
- Max. number of aspiration openings: 64 (2 x 32)
- Max. duct length: 560 m (2 x 280)
- Consumption at rest: 240 mA
- Maximum power consumption in alarm: 250 mA
SENSITIVITY OF ALARM RESPONSE | ||
REFERENCE | MODULE 1 | MODULE 2 |
AETP5-F2-50. | 0.5% | 0.5% |
AETP5-F2-1050 | 0.1% | 0.5% |
AETP5-F2-10 | 0.1% | 0.1% |
AETP5-F2-0150 | 0.015% | 0.5% |
AETP5-F2-0110 | 0.015% | 0.1% |
AETP5-F2-01 | 0.015% | 0.015% |
Titanus Racksens
TITANUS RACK·SENS® modular systems fire protection for the control of electronic cabinets of 19 inch format.
The system meets the highest requirements regarding security in the IT sector and for the first time, it provides the advantages of the improved TITANUS systems for smoke detection by air sampling, for the control of 19″ equipment.
TITANUS RACK·SENS® is available upon request by the customer, as:
- 19″ module / 1HU for earliest possible detection of fires.
- 19″ module / 2 HU for earliest possible detection of fires with fire extinguishing integrated. Its many different versions and extension accessories allow for its individual adaptation to customer’s requirements.
They provide:
- 2 alarm levels
- 6 frontal Leds indicating the status: service, disconnection, shot, pre-alarm, alarm and fault.
- Relays free of output voltage for alarm and fault.
- Optional 10-digit bar graph that keeps the user informed about the current smoke level.
- Output for remote indicator
- Certificates EN54-20 nº: 0786-CPD-20322• VdS Approval nº: G206004
AETR2-C. TITANUS RACK-SENS® 2 heights (2 cylinders)
REFERENCE | DETECTORS | SENSITIVITY | LEVEL INDICATOR |
AETR-50 | 1 | 0.5% | NO |
AETR-50B | 1 | 0.5% | SI |
AETR-10 | 1 | 0.1% | NO |
AETM-10 | 1 | 0.1% | SI |
REFERENCE | DETECTORS | SENSOR DETECTOR 1 | SENSOR DETECTOR 2 | IND. DE LED | CYLINDRES |
AETR2-1D | 1 | 0.5% | NO | 1 | |
AETR2-1DB | 1 | 0.5% | SI | 1 | |
AETR2-1D2C | 1 | 0.5% | NO | 2 | |
AETR2-1D2CB | 1 | 0.5% | SI | 2 | |
AETR2-2D | 2 | 0.5% | 0.1% | NO | 1 |
AETR2-2DB | 2 | 0.5% | 0.1% | SI | 1 |
AETR2-2D2C | 2 | 0.5% | 0.1% | NO | 2 |
AETR2-2D2CB | 2 | 0.5% | 0.1% | SI | 2 |