Thermal detector recommended for high humidity environments. Temperature range: -40°C. 70°C. Humidity range: up to 98%. CE certified according to EN54-7 and for MARINA.
Archivos
Marine-series multi-sensor detector
Optical thermal detector recommended for high humidity environments. Temperature range: -40°C. 70°C. Humidity range: up to 98%. CE certified according to EN54-7/EN 54-5 and for MARINA.
Intrisically safe thermovelocimetric detector
Intrinsically secure low profile heat detector. Classified as II 1G EXia IIC (T5) (T4) in BASEEFA. It meets the En54-7 norm, thermal class A1R. CE and LPCB certificates, according to EN54-7.
ATEX Sirens
Intrinsically safe Syrex Siren providing a sound signal in dangerous area. AE/IS-S Classified ATEX II 1G EEx ia IIC T4. Provided with 49 selectable tones. IP65. AE/IS-DB5 Classified ATEX II 1G Ex ia IIC – IP65.
Intrinsically safe alarm button
Intrinsically safe alarm button for indoors, suitable for installations in hazardous areas. Classified as EX II 1G EExia IIC T4. It meets the EN 54-11 standard.
Central zone unit for the detection of carbon monoxide
Central control of a zone for the detection of carbon monoxide. It has a 4-20mA input, bar of LED lights, indicating the detected gas concentration. Supplied with 3 alarmrelays, fault relay and a RESET function. Power supply: 230V AC and Continuar leyendo
Central zone unit for methane gas detection or GLP
Central control of a zone for the detection of methane gas or LPG. It has a 4-20mA input, bar of LED lights, indicating the detected gas concentration. Supplied with 3alarm relays, fault relays and a RESET function. Power supply: 230V AC Continuar leyendo
Digital central unit of a zone for gas detection
Digital central unit of one zone for gas detection and built-in installation, equipped witha luminous display, a 4-20mA input, alphanumeric monitor that indicates the gas concentration detected in real time. Supplied with 3 alarm relays, fault relays and a RESET function. Power Continuar leyendo
Detection probe for water
Formed by: a printed circuit with terminals for its connection to the detector and contacts that detect the presence of water. Mounted in an ABS cabinet of 40 x30 x15 mm. Up to three can be connected in a single detector.
Intrinsically safe, optical smoke detector
Low profile, intrinsically safe, optical smoke detector. Classified II 1G EXia IIC (T5) (T4) in BASEEFA. Certificates CE and LPCB, according to EN54-7 norm.
Flood detector at 12 and 24 V
Formed by: • Power supply with an encapsulated transformer. • Electronic module with LEDs for alarms and service.Buzzer alarm, encapsulated relay with free of tension output and an entry for water sensing probes. Mounted in an ABS cabinet of 130x70x50 Continuar leyendo
Flood detector at 230 V
Formed by: Power supply with an encapsulated transformer. Electronic module with LEDs for alarms and service.Buzzer alarm, encapsulatedrelay with free of tension output and an entry for water sensing probes. Mounted in an ABS cabinet of 130x70x50 mm.
Increased security alarm button
Increased security alarm button resistant to an explosion. Suitable for installations in hazardous areas. Classified as EX II 2G EExed IIC. Protection IP66. Temperature: – 20 ºC to +50 ºC Plastic material reinforced with GRP glass.Dimensions: 126x120x75mm
ATEX Flameproof siren
Intrinsically safe Syrex Siren providing a sound signal in dangerous areas. Classified ATEX II 2G EEx ia IIC – IP65.
Algorithmic control panel of 1 loop
Panel for fire control with capacity for 1 loop of 125 equipments each,to which the detectors, switches, modules for manoeuvres, for control and otherelements that make up the installation, all connect. Switched power supply of 27.2 Vdc at 2 A. Continuar leyendo