![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE-M-BC.jpg)
Heated base designed for use in cold environments, where condensation or a high risk of frost may affect the operation of the detector.
The heated base raises the temperature of the detector at around 10 °C.
For its functioning, a backup auxiliary power supply is needed.
Power consumption:100 mA/ 24 V.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-M-OP.jpg)
Optical smoke detector recommended for areas with high humidity.
- Temperature range:-40°C to 70°C.
- Humidity range: up to 98%.
- Certificates CE, according to EN54-7 and for MARINE.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-M-OPT.jpg)
Optical thermal detector recommended for high humidity environments.
Temperature range: -40°C. 70°C.
Humidity range: up to 98%.
CE certified according to EN54-7/EN 54-5 and for MARINA.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-m-t.jpg)
Thermal detector recommended for high humidity environments.
Temperature range: -40°C. 70°C.
Humidity range: up to 98%.
CE certified according to EN54-7 and for MARINA.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE90-FAVS.jpg)
Detector indicated for the detection of flame in those places where initial fire can beproduced, instead of smoke.
- Operating temperatures from 0 ºC to 45 ºC
- Power consumption: 320 μA (at rest), 45-50 mA (alarm).
- Consumption between 12-28 V CC.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE90-FEN.jpg)
Thermostatic-heat detector for special installations, such as reservoirs and tanks withliquids. Several models exist that are calibrated at different temperaturas (61º, 71º, 88º, 98º, 107º, 135º,163º,182º, 232º,260º,315º y 398º), in both open and closed circuit.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410ae90-fen-ex.jpg)
It has the same features as above, but is certified by ATEX ExII C, 2GD EExd II T6
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE90-FENIP65.jpg)
A les mêmes caractéristiques que le précédent mais est logé dans une boîte en aluminium IP65 10cm
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-IS-DB3.jpg)
Intrinsically safe Syrex Siren providing a sound signal in dangerous areas.
Classified ATEX II 2G EEx ia IIC – IP65.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-is-db5.jpg)
Intrinsically safe Syrex Siren providing a sound signal in dangerous area.
AE/IS-S Classified ATEX II 1G EEx ia IIC T4. Provided with 49 selectable tones. IP65.
AE/IS-DB5 Classified ATEX II 1G Ex ia IIC – IP65.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE-IS-F.jpg)
Xenon focus of augmented security, manufactured in corrosion resistant plastic, suitablefor dangerous aerial installations.
- Classified as ATEX Ex II 1G EExia II CT4
- Classified as ATEX Ex II 1G EExia II BT4
- Protection: IP66
- Temperature: -55ºC to +60ºC.
- Voltage: 24V DCCurrent: 55 mA
AE/IS-FXB11. Xenon focus for increased security
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-IS-S.jpg)
Intrinsically safe Syrex Siren providing a sound signal in dangerous area.
- AE/IS-S Classified ATEX II 1G EEx ia IIC T4.
- Provided with 49 selectable tones. IP65.
- AE/IS-DB5 Classified ATEX II 1G Ex ia IIC – IP65.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-v-asfind.jpg)
High acoustic power siren with focus for industrial use.
Certified according to EN 54-3.
Protection: IP66. Sound level: 120dB at 24Vcc