![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ar-fl-ir2.jpg)
Dual infrared flame detector, mounted in zinc alloy casing. Its micro-processor technology allows it to work with different levels of flame intensity and operates normally under adverse conditions. The detector sensitivity can be adjusted in accordance with the EN 54-10 regulation.
- Certified EN54-10 .
- Supply voltage 14 – 30 VDC .
- Current supplied 3/9, 4/8/14, 4-20, 8-20 mA .
- Field of view 90° min. Conical. Spectral response (IR) 1 to 2.7 microm.
- Operation temperature -10°C to 55°C, Storage temperature -20°C to 65°C.
- Non-condensing relative humidity 95%.
- Protection range IP65.
- Weight 2 kg
![](https://aguilera.es/en/wp-content/uploads/sites/2/2015/10/201408AE-FL-IR2EX.jpg)
Dual infrared flame detector mounted in flameproof casing Its micro-processor technology allows it to work with different levels of flame intensity and operates normally under adverse conditions. The detector sensitivity can be adjusted in accordance with EN54-10.
- Supply voltage 14 – 30 VDC .
- Current supplied 3/9, 4/8/14, 4-20, 8-20 mA .
- Field of view 90° min. Conical. Spectral response (IR) 1 to 2.7 microm.
- Operation temperature -10°C to 55°C, Storage temperature -20°C to 65°C.
- Non-condensing relative humidity 95%.
- Protection range IP66
- Weight 2.5 kg
- IEC EEx d IIC T6
![](https://aguilera.es/en/wp-content/uploads/sites/2/2015/09/201408AE-FL-IR3.jpg)
IR³ flame detector with fire-resistant cover. Highly sensitive micro-processor which allows it to operate through smoke, oil, dust or water vapour. Sensitivity adjustable according to the EN54-10.
- Supply voltage 14 – 30 VDC .
- Current supplied 3/9, 4/8/14, 4-20, 8-20 mA .
- Field of view 90° min. Conical
- Responds to a wave length ranging from 0.75 to 2.7μm emitted by all type of fire.
- Operation temperature -10°C to 55°C, Storage temperature -20°C to 65°C.
- Non-condensing relative humidity 95%.
- Protection range IP65
- Weight 2 kg. Dimensions : 108 x 142 x 82 mm
![](https://aguilera.es/en/wp-content/uploads/sites/2/2015/09/201408AE-FL-IR3EX.jpg)
IR³ flame detector with fire-resistant cover. Highly sensitive micro-processormwhich allows it to operate through smoke, oil, dust or water vapour. Sensitivity adjustable according to the EN54-10.
Responds to a wave length ranging from 0.75 to 2.7μm emitted by all type of fire. Detects non-visible gas fires such as hydrogen gas fires. IR³ detectors.
Allows to discriminate between flames and false radiation sources of the IR, as the combination of filters and signal processing prevents from false alarms.
- Supply voltage 14 – 30 VDC .
- Current supplied 3/9, 4/8/14, 4-20, 8-20 mA .
- Field of view 90° min. Conical.
- Spectral response (IR) 1 to 2.7 microm.
- Operation temperature -10°C to 55°C, Storage temperature -20°C to 65°C
- Non-condensing relative humidity 95%.
- Protection range IP66
- Weight 2.5 kg; Dimensions: 146 x 150 x 137 mm
- IEC EEx d IIC T6 Certified”
![](https://aguilera.es/en/wp-content/uploads/sites/2/2015/09/201408AE-FL-UVIR2.jpg)
Flame detector with double technology infrared sensors (IR) and ultraviolet (UV: 185 a 260 nm). Detection cone 90º and detention distance up to 45 metres. Low consumption (8mA). A relay output is incorporated. Programmable sensitivity. Filters and analysis through micro-processor for false alarm elimination.
- Spectral response in the infrared: 1 at 2,7um.
- Power supply 14-30Vcc.
- Consumption: 20mA.
- Certified IEC EEx d IIC T6.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2016/01/201408ae-fl-uvir2ex1.jpg)
Flame detector with double technology infrared sensors (IR) and ultraviolet (UV: 185 a 260 nm). Detection cone 90º and detention distance up to 45 metres.
- Low consumption (8mA). A relay output is incorporated. Programmable sensitivity.
- Filters and analysis through micro-processor for false alarm elimination.
- Spectral response in the infrared: 1 at 2,7um.
- Power supply 14-30Vcc. Consumption: 20mA.
- Zinc alloy casing with IP66-protection.”
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE-IS-B.jpg)
Socket for intrinsic detectors that allows the exchange of the two previous smoke detectors.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-is-dop.jpg)
Low profile, intrinsically safe, optical smoke detector.
Classified II 1G EXia IIC (T5) (T4) in BASEEFA.
Certificates CE and LPCB, according to EN54-7 norm.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-is-dopt.jpg)
Low profile, intrinsically safe, optical heat detector.
Classified II 1G EXia IIC (T5) (T4) in BASEEFA.
Certificates CE and LPCB, according to EN 54-7 norm.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-IS-DTV.jpg)
Intrinsically secure low profile heat detector.
Classified as II 1G EXia IIC (T5) (T4) in BASEEFA.
It meets the En54-7 norm, thermal class A1R.
CE and LPCB certificates, according to EN54-7.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201410AE-M-BC.jpg)
Heated base designed for use in cold environments, where condensation or a high risk of frost may affect the operation of the detector.
The heated base raises the temperature of the detector at around 10 °C.
For its functioning, a backup auxiliary power supply is needed.
Power consumption:100 mA/ 24 V.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-M-OP.jpg)
Optical smoke detector recommended for areas with high humidity.
- Temperature range:-40°C to 70°C.
- Humidity range: up to 98%.
- Certificates CE, according to EN54-7 and for MARINE.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE-M-OPT.jpg)
Optical thermal detector recommended for high humidity environments.
Temperature range: -40°C. 70°C.
Humidity range: up to 98%.
CE certified according to EN54-7/EN 54-5 and for MARINA.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408ae-m-t.jpg)
Thermal detector recommended for high humidity environments.
Temperature range: -40°C. 70°C.
Humidity range: up to 98%.
CE certified according to EN54-7 and for MARINA.
![](https://aguilera.es/en/wp-content/uploads/sites/2/2014/10/201408AE90-FAVS.jpg)
Detector indicated for the detection of flame in those places where initial fire can beproduced, instead of smoke.
- Operating temperatures from 0 ºC to 45 ºC
- Power consumption: 320 μA (at rest), 45-50 mA (alarm).
- Consumption between 12-28 V CC.