Referencia: AECS/SEC15

d-LIST Cable

Sensors cable which can be used at temperatures between -40ºC and +85ºC (+120ºC during short) records the temperatures with a 0,1º resolution.
Perfect for places with difficult access since it does not need maintenance or adjustments.
The cable is made of:
• 2 conductors plane cable with mounted hybrid circuits
• Packing material with relief traction (to secure the cable in case of fire)
• Integrated aluminium screen.
• External cover free of halogens and flame retardant.
It is supplied with different distances between sensors according the variant. The sensors inside the cable are separated with a distance of 1,2,3,4, or 5 m. Also it can be supplied made to order with other distance between specific sensors from 0,25 to 10m.
Other characteristics:
• Cable cover material free of halogens, flame retardant (conform to EN 60332-1-2, EN 60332-2-2 and IEC 60754-1)
• Approx. Diameter. 15 mm
• Weight per m 0,35 kg/m
AECS/SEC15-1 Sensors Cable every 1m
AECS/SEC15-2 Sensors Cable every 2m
AECS/SEC15-3 Sensor Cable every 3m
AECS/SEC15-4 Sensor Cable every 4m
AECS/SEC15-5 Sensor Cable every 5m

Referencia: AEC-430

Linear detection modules of temperature

These modules monitor 1 or 2 cable zones. Powered with 24Vdc. Outputs for alarm& fault relays. Models with display for point identification alarm, in cabinet with IP66and zener barrier for installations in dangerous classified areas.

  • AEC-120.Standard module, without housing and without display, mounted with a DIN rail bracket.
  • AEC-430. Standard module, with 2 zones, with no cabinet, no display.
  • AEC-430D. Standard module with 2 zones, with no cabinet and with display.
  • AEC-430E. Standard module with 2 zones, cabinet with (IP66) and no display.
  • AEC-430DE. Standard module with 2 zones, cabinet with (IP66) and with display.
  • AEC-430E-I.Standard module with 2 zones, cabinet with (IP66) without display and a ZENER barrier.
  • AEC-430DE-I. Standard module with 2 zones, cabinet with (IP66) with display and a ZENER barrier.
Referencia: AEC-CC

Anchor bolts

  • AEC-CCN. Anchor bolts in white nylon
  • AEC-CCP. Anchor bolts in beige polypropylene
  • AEC-CCAI. Anchor bolts in stainless steel
Referencia: AEC-CJCF

Junction box in fibreglass.

  • AEC-CJCF. Junction box in fibreglass with a ruler guide for the terminals.
  • AEC-CJFLF.Junction cabinets, in fibreglass (With an 8K2 resistance)
Referencia: AEC-CJCP

Plastic connection cabinets

  • AEC-CJCP.Plastic connection cabinets
  • AEC-CJFLP. Plastic connection cabinets (for module AEC-430)
Referencia: AEC-EAPA

Metric adapter for the position of alarm point

Metric adapter for the position of alarm point that converts almost any digital multimeter,in a counter of the alarm point position. If the cable was cut to locate and show witha reading the distance in feet (meters optionally), it helps to know the exact locationof the fire.

Test equipment

Metric adapter for the position of alarm point. Convert almost any digital multimeter,
in a counter of the alarm point position. If the cable was cut to locate
and show witha reading the distance in feet (meters optionally), it helps to
know the exact locationof the fire.
AEC-ELF. Fault localiser system

Referencia: AEC-EPC

Detector cable EPC type

The linear heat detector is a thermal cable that consists of two conductors of twistedsteel, covered by a layer of heat sensitive polymer. Upon reaching the temperature,a contact between the two conductors is provoked, generating
an alarm signal. Available in various triggering temperatures.

As its main features we underline:

  • Its resistivity of 0.65 /m allows us to identify the distance to the source of heat.
  • Suitable to protect cable trays, conveyor tunnels, petrochemical, storage rooms,machinery…
  • “”-M”” models with a load-bearing external steel wire for ease of installation.
  • 4 mm diameter.
  • Extended coverage area of up to 15.2 meters.
  • Approvals by UL and FM.
ALARM TEMPERATUREREFERENCE
68 ºCAEC-EPC68.
68 ºC cable clampAEC-EPC68M
88 ºCAEC-EPC88
88 ºC cable clampAEC-EPC88M
105 ºCAEC-EPC105
105 ºC cable clampAEC-EPC105M
138ºCAEC-EPC138
138ºC cable clampAEC-EPC138M
180ºCAEC-EPC180
180ºC cable clampAEC-EPC180M
Referencia: AEC-EPR

Detector cable EPR type

The linear heat detector is a thermal cable that consists of two conductors of twisted steel, covered by a layer of heat sensitive polymer. Upon reaching the temperature,a contact between the two conductors is provoked, generating an alarm signal. Available in various triggering temperatures.

As its main features we underline:

  • Its resistivity of 0.65 /m allows us to identify the distance to the source of heat.
  • Suitable to protect cable trays, conveyor tunnels, petrochemical, storage rooms,machinery…
  • “”-M”” models with a load-bearing external steel wire for ease of installation.
  • 4 mm diameter.
  • Extended coverage area of up to 15.2 meters.
  • Approvals by UL and FM..

External covering out of polypropylene with environmental resistance, resistant to abrasion, UV protection, resistant to oils and high performance at elevated temperatures.

 

ALARM TEMPERATUREREFERENCE
68 ºCAEC-EPR68
68 ºC Cable clampAEC-EPR68M
88 ºCAEC-EPR88
88ºC Cable clampAEC-EPR88